Dear All: 

I recently sent around discussions of ways to measure/estimate drug concentrations both in living animals (aptamer-based probes, Kevin Plaxco’s group) and with sufficient spatial resolution to permit construction of 2d/3d drug concentration maps (MALDI-MSI, David Perlin’s group).

In the context of our efforts to learn to better apply PK-PD (e.g., the 14-15 June 2017 NIAID PK-PD workshop), these notes generated a lot of interest and in particular Ed Weinstein (FDA) made me aware of a book chapter in which he and his co-authors had looked at a range of such techniques.

Finding this intriguing, I worked with Kevin, David, and Ed to prepare a summary of the range of current techniques for doing something that you could loosely call PK in high resolution by time and/or space. Several ways of categorizing the methods are shown in the table below and you’ll find more details on each in this downloadable summary document. It’s fascinating to see them side-by-side and realize the wealth of opportunities that exist.

Each approach has strengths and weaknesses but I must say that MALDI-MSI and aptamer-based probes really standout as exciting new tools by offering strong spatial information (MALDI-MSI) or easily obtained continuous drug measures (aptamer-based probes) based in both cases on measurements of the unmodified analyte

Overview of techniques: Specialized probe and/or modified analyte vs. general approach to detection of unmodified analytes

Continuous, with
potential for in vivo
Single* time point
Offers
spatial
resolution
Fluorescent probeHyperpolarized NMR/MRIPET ImagingPhotoacoustic imagingLow energy (3H or 14C) radio-labeled analyte
with Whole-Body AutoradiographyMALDI-MSILaser-capture microdissection
Single*
site
Aptamers on a probeMicrodialysisGrind tissue & assay extract

*Of course, any single time point or single site method could be extended by doing serial sampling but there are practical limits to how much of this you can do.

Rough rank order of spatial imaging resolution methods:

  1. Higher resolution: MALDI-MSI, autoradiography
  2. Lower resolution: Fluorescent probe, Hyperpolarized NMR/MRI, PET Imaging, Photoacoustic imaging, Laser-capture microdissection

Absolute analyte concentration data: (1) Aptamers on a probe, (2) Microdialysis (with difficulty), (3) Laser-capture microdissection, and (4) Grind tissue & assay extract

If this intrigues, you may also want to look both at this book and PK-specific chapter within it:

  1. Book: Imaging Infections : From Bench to Bedside. S. K. Jain.: https://link.springer.com/book/10.1007%2F978-3-319-54592-9
  2. Chapter in said book Ordonez, A. A., L. E. Bambarger, S. K. Jain and E. A. Weinstein (2017). Biodistribution and Pharmacokinetics of Antimicrobials. Imaging Infections : From Bench to Bedside. S. K. Jain. Cham, Springer International Publishing: 209-222. :https://link.springer.com/chapter/10.1007/978-3-319-54592-9_10

And to round out this summary of PK-related ideas, you might also want to review the material from

MANY thanks to Ed, David, and Kevin for provoking this interesting exploration!

All best wishes, –jr

John H. Rex, MD | Chief Medical Officer, F2G Ltd. | Chief Strategy Officer, CARB-X | Expert-in-Residence, Wellcome Trust. Follow me on Twitter: @JohnRex_NewAbx. See past newsletters and subscribe for the future: https://13.43.35.2/blog.html

Upcoming meetings of interest to the AMR community:

Share

HLM on AMR at UNGA: The end of the beginning

Aside: Please refer to our UNGA 2024 webpage for additional post-HLM notes and updates. Dear All (and with thanks to Damiano for co-authoring), Last week in NYC, the UN General Assembly (UNGA) and all its surrounding activities created a lot of energy (not to mention a giant traffic jam)! After a series of side meetings

Without action, AMR costs go from $66b to $159b/yr by 2050

Dear All, A new paper from Anthony McDonnell and a team led by the Center for Global Development extends estimates of the health-related impact of AMR (e.g., death) to a consideration of the economic ($) cost of AMR. To follow the plot, here are the links you will need: The new paper: “Forecasting the Fallout

UN TV: You can watch the AMR High-Level Meeting at UNGA

Dear All, The AMR HLM (High-Level Meeting) at the UN General Assembly starts at 10a ET today.  You can watch it here on UN TV: https://webtv.un.org/en/asset/k11/k11knc6w2t Addendum: It’s available for replay at that same link. See also the 1 Oct 2024 newsletter for a review of the HLM. All best wishes, –jr John H. Rex, MD

PACE: A £5m funding round for diagnostics

Dear All, The peri-UNGA week is generating a lot of activity! Having about a year ago launched a £30m fund for support of AMR innovation with a call for therapeutic projects (30 Oct 2023 newsletter; I am told that awards will be announced soon), PACE (Pathways to Antimicrobial Clinical Efficacy, a joint project of LifeArc,

Scroll to Top